Battery pack imbalance detection

Written by Alexander Tillheden | Nov 9, 2026, 2:24:51 PM

Intro

This public transport operator runs a big electric bus fleet with buses from several manufacturers. Each bus starts the day with the range needed to complete its trips. But sometimes the bus would not make it without having an emergency opportunity charge break. So the operator wanted to know why this was happening and see the correct capacity of its buses so it can plan with the capacity for each bus in mind.

Challenge

After a full night of charging, some buses started a day with much less range than they normally should have. During the day, the state of charge could also fall suddenly by a large step. This would happen all year round, so cold weather could not explain it. The staff blamed the chargers, the weather, or sometimes even the drivers, but none of those was the true cause.

This bus type carries five battery packs in its system. A faulty connection was taking one or maybe even two packs offline. The bus then runs on four packs and has lost 20% of its capacity, or even 40%, if the second pack dropped out. But the dashboard would still show a hundred percent state of charge because it didn't know that one pack was missing.